Loading...

info@t-injecta.sk     +421 32 7709 991     

Cannulas

cannulas


Cannulas manufacturing portfolio

  • Silicone covered tip
  • Surface roughened by sandblasting or with LASER technology
  • End of lancet specially grinded to pencil point
  • Pre-sterilization by ETO in order to ensure low Cfu level
  • Final packing in CLEAN rooms class ISO 7 and/or ISO 8
  • Main angle from 6° with tolerance +/- 0,5°
  • 3-cycle cleaning procedure in special solutions together with ultrasonic
  • Siliconization min. at 5 mm length, silicone hardened
  • Packaging in magazines or bundles (plastic tins)


Cannulas needles

• Made in compliance with EN ISO 9626 standard using the state-of-the–art technology that ensures excellent sharpness of the point

• Made of medical stainless steel grade 1.4301 (AISI 304), 1.4306 (AISI 304L) or 1.4404 (AISI 316L)

• Manufactured in diameter G33-G10 (from 0,2 mm till 3,40 mm) in length from 9 -200 mm

• Rounded or chamfered cannula needle end, free of burrs

• One -or both side grinding using different bevels 
               > Single bevel or 3-bevel tip with side- or back grinding 
               > Tip with back eye or side hole 
               > Bent tip

• Packed in a plastic pots with foam protection against damage

• Supplied as non-siliconized, upon customer´s request can be supplied also siliconized cannula needles


Outer diameter in mm Outer diameter in Gauge Wall thickness Outer diameter in mm Outer diameter in Gauge Wall thickness
0,20 33 RW/TW/XTW* 0,80 21 RW/TW/XTW*
0,23 32 RW/TW/XTW* 0,90 20 RW/TW/XTW*
0,25 31 RW/TW/XTW* 1,10 19 RW/TW/XTW*
0,30 30 RW/TW/XTW* 1,20 18 RW/TW/XTW*
0,33 29 RW/TW/XTW* 1,40 17 RW/TW/XTW*
0,36 28 RW/TW/XTW* 1,60 16 RW/TW/XTW
0,40 27 RW/TW/XTW* 1,80 15 RW/TW/XTW*
0,45 26 RW/TW/XTW* 2,10 14 RW/TW/XTW*
0,50 25 RW/TW/XTW* 2,40 13 RW/TW/XTW*
0,55 24 RW/TW/XTW* 2,70 12 RW/TW/XTW*
0,60 23 RW/TW/XTW* 3,00 11 RW/TW/XTW*
0,70 22 RW/TW/XTW* 3,40 10 RW/TW/XTW*

Available material quality 1.4301 (AISI 304) and 1.4306 (AISI 304L), material 1.4404 (AISI 316L) with limits upon request
* Available with limits, please contact Customer service

 

Basic cannula application

  • hypodermic needle
  • blood collection needle
  • pen needle
  • fistula needle
  • IV cannula needle
  • insulin syringe needle
  • pre-filled syringe needle
  • blood bag needle
  • dental needle


Bevels

single cut 3 bevel back cut fistula
Single bevel 3-bevel with side grinding 3-bevel with back grinding Tip with back eye

 

 side hole  bend tip    
Tip with side hole Bent tip  

 

 

 Surfaces

 grinding  laser    
Sandblasting Laser technology